If you get the "Sorry, the file cannot be displayed. There seems to be a technical issue ..." error when trying to view an image, a workaround is to click on the cog icon in the upper right side of the media viewer, and then select "Disable Media Viewer". We are aware of the problem and are looking for a solution.

2201

From TekWiki
Jump to: navigation, search
Tektronix 2201
10 MHz, 20 MS/s analog/digital scope
Tektronix 2201

Produced from 1988 to 1993

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 2201 is a combined 10 MHz / 20 MS/s analog/digital oscilloscope introduced in 1988.

Specifications

Rise time 17.5 ns
Bandwidth 20 MHz (analog)
Deflection 5 mV/Div to 5 V/Div, 1-2-5, ±3%
Sweep (analog) 50 ns/Div to 0.5 s/Div,  ×10 magnifier (5 ns/Div)
Sweep (digital) 20 μs/Div to 0.5 s/Div,  ×100 store to 50 s/Div)
Input impedance 1 MΩ // 25 pF
Sampling rate 10 MS/s, both channels simultaneously (two ADCs)
Record length 2K per channel
Resolution vertical 8 bit, horizontal 11 bit
Probes Two P6103 10X 2M Probes
CRT 8 cm × 10 cm, 12.5 kV acceleration
Power 95−128 VAC / 185−250 VAC, 48−440 Hz, 70 W
Size and weight 138 mm (w) × 380 mm (h) × 438 mm (d), 7.6 kg
Features
  • Readout
  • Cursors
  • TV and P-P auto trigger
  • X-Y operation (2 MHz X BW), ±3° from DC to 50 kHz
  • One trace reference memory
  • RS-232 interface (option 12) with hardcopy function (HPGL, Epson FX)